Colour code for easy identification of matching connections. Strong colours can be distinguished even in bad lighting conditions. Available in eight different colours, at the moment.
Fittings equipped with adapters NightLight can be easily seen in the dark because of the fluorescent luminous paint.
Easy conversion possible for all parts.
Twist in fire hoses can cause uncontrolled movements of connected fittings. This can be avoided by using adapters with a ball bearing threaded tail piece at the fitting to have a "full time swivel" under pressure. Therefore AWG Turbo-Nozzles have "full time swivel" adapters as standard.
Adapters with male thread are supplied without flat seals.
In the case of pneumatic conveying of powder and granulates in hoses with Storz couplings, an additional safeguard may be advisable, since strong vibration and the torsional stresses often present in hose lines might cause uncoupling during operation.
| Switch make: |
|
Balluf BES 516-356-E4-Y |
| Operating voltage: |
|
10-30 volt three-phase a.c. |
| Permissible current loading: |
|
= 130 mA d.c. |
... Show text
| Switch make: |
|
Balluf BES 516-356-E4-Y |
| Operating voltage: |
|
10-30 volt three-phase a.c. |
| Permissible current loading: |
|
= 130 mA d.c. |
| Switch function: |
|
make contact |
| Output circuit: |
|
PNP |
| Protective standard DIN 40 050: |
|
IP 67 |
| Ambient temperature: |
|
- 25°C - +70°C |
| Cable length: |
|
3 m (Ř=3 x 0,34) |
Short-circuit resistant against changeover of positive and negative, as well as against inductive voltage peaks. When protective circuit has cooled, the output signal is active again.
Hide text
For fitting to pipework for filling tanks and silos from tank trucks, as well as to coupling stations for in-plant product distribution. Preferably for pipework in which bulk goods or liquids are carried.
... Show text
For fitting to pipework for filling tanks and silos from tank trucks, as well as to coupling stations for in-plant product distribution. Preferably for pipework in which bulk goods or liquids are carried. Signalling of filling processes - Activation of overfill safeguard - Energization of the exhaust air filters - Opening of stop valves - Closing of silo pilots - Release of the feed process - Checking of line connection - Discharge prevention during filling - Changeover of silo scales to fill recording.
Limit switch as a position sensor with snap-action contact
| Switch make: |
|
Telemecanique XCM - A 110 |
| Switch function: |
|
1 break contact + 1 make contact |
| Contact rating: |
|
6 A at 250 Volt AC |
| Protective standard: |
|
IP 67 |
| Ambient temperature: |
|
-25°C - +70°C |
| Cable lengths-Ř: |
|
2 + 10 m (5x0,75) |
Hide text